Furnace Burner Upgrade at a Changodar Forging Unit: 16% Lower Gas Use and 35% Faster Billet Heating
FORGING & METAL REHEATING FURNACE BURNER UPGRADE Burner Automation

Furnace Burner Upgrade at a Changodar Forging Unit: 16% Lower Gas Use and 35% Faster Billet Heating

How a better burner control and gas train setup helped a Changodar forging unit heat billets faster and use 16% less gas.

🏢 Client: Precision Forging & Auto Components Unit • 📍 Location: Changodar Industrial Area, Ahmedabad, Gujarat • ⏱️ Timeline: 24 Hours, Sunday Shutdown • 📅 Oct 2026
⚠️

The Challenge & Technical Bottleneck

The unit used a gas-fired billet reheating furnace to heat steel billets before forging. The old burner control was manual-heavy, and the flame often went out when gas pressure dropped. Operators had to relight it by hand, and each relight cost 15 to 20 minutes of lost heating time. The billets also heated unevenly, so the forging press sometimes got billets at different temperatures. Gas consumption was high because the burner was running rich to avoid flame failure.

💡

Our Engineering Solution & Retrofit Execution

We inspected the furnace on site, checked the gas supply pressure, and studied how the operators were running the burner. Then we fitted a Kromschroder BCU 460 burner control unit with a UVS 10 UV flame sensor, so the flame is monitored continuously and the burner restarts safely if it trips. We replaced the old gas train with a Dungs valve train with pressure switches for stable and safe gas flow, and added a Honeywell modulating actuator for smooth air control. All parts came from our ready stock. We completed the installation in a 24-hour Sunday shutdown, tuned the air-gas ratio on live furnace readings, and trained the operators.

📈

Business Results, Fuel Savings & Safety Compliance

The furnace now holds a steady flame, even when gas pressure moves. Billets reach forging temperature about 35% faster, and the heat is more even across the batch. Gas consumption dropped by around 16%. There have been no flame-out trips in the first 90 days, so operators no longer lose time relighting. The plant also gained safer operation, since the new control and gas train follow proper flame-failure shutdown practice.

Detailed Case Story & Technical Execution

In a forging unit, every minute the furnace is not at temperature is a minute the press sits idle. A Changodar forging plant was losing exactly this time to flame-outs and uneven heating. This is how we, at Gajanand Engineering And Services, fixed the burner side of the problem.

Why the Client Chose Us?

  • Original Kromschroder, Dungs and Honeywell parts available from our Ahmedabad stock
  • Site inspection and gas pressure check before any proposal
  • Installation done in a single Sunday shutdown, so no production day was lost
  • Burner repair and service experience since 2017

Our Approach (Step by Step):

  1. Site study: furnace, burner, gas pressure and operator practice.
  2. Proposal: a clear parts list, cost and shutdown plan.
  3. Installation: control unit, flame sensor and gas train in 24 hours.
  4. Tuning: air-gas ratio set on live furnace readings.
  5. Training: operators briefed on safe start-up and shutdown.
  6. Support: AMC visits and spares backup.

Client Feedback

“Earlier we kept losing time relighting the burner. Now the furnace just runs, and our press gets billets on time. The team was quick and clear in explaining everything.” — Production Head

FAQs

1. Why does a furnace burner flame go out suddenly?

  • Common causes are low or fluctuating gas pressure, a dirty or weak flame sensor, or a faulty valve. A site check shows the exact reason.

2. Can you upgrade the burner control without changing the furnace?

  • Yes. In most cases, we can fit a new control unit, flame sensor and gas train on the existing furnace and burner.

3. How do I know the burner is running efficiently?

  • We check flue gas readings and gas consumption before and after tuning. A correct air-gas ratio gives steadier heat and lower fuel use.

4. Do you supply spares for Kromschroder, Dungs and Honeywell?

  • Yes. We supply original spares for these and many other brands, with a GST invoice.

5. Do you provide burner AMC for furnaces?

  • Yes. Our AMC covers regular inspection, cleaning, tuning and priority support for spares.


Is your furnace burner tripping, heating unevenly or using too much gas? Call us on +91 97277 74416 or email info@gajanandburner.in for a free site assessment

SOLVE YOUR PLANT'S BURNER DOWNTIME

Facing a Similar Combustion or Sequence Controller Challenge?

Talk directly with Sukhdevbhai Raval and Gajanand's engineering specialists. We verify part codes, provide schematic wiring diagrams, and dispatch 100% genuine spares across India.

WhatsApp Engineering Lead 💬

📋 Project Snapshot

Client / Plant Precision Forging & Auto Components Unit
Industry / Sector Metal Forging & Billet Reheating
Coverage / Location Changodar Industrial Area, Ahmedabad, Gujarat
Execution Timeline 24 Hours, Sunday Shutdown
Key Equipment & Spares Kromschroder BCU 460 Burner Control Unit + Kromschroder UVS 10 UV Flame Sensor + Dungs Gas Valve Train & Pressure Switches + Honeywell Modulating Actuator
MEASURED RESULTS

Key Impact Highlights

16% Gas Consumption Cut
35% Faster Billet Heat-up
24 Hrs Installation Window
📞

Immediate Breakdown Assistance

Need quick burner diagnostics or emergency stock delivery in Ahmedabad, Kadi, Surat, or Ankleshwar?

Call +91 97277 74416